Chapter 13 LIST OF ERROR MESSAGES
559
Code (HEX) Error message Description
348 ‘V-Timing EQP-Fp’ Over Limit EQP-FP in the vertical timing data is outside the setting range.
349 ‘V-Timing EQP-Bp’ Over Limit EQP-BP in the vertical timing data is outside the setting range.
34A ‘V-Timing’ Data Error Error other than those described above in the vertical timing data.
34E DDC2 Line Error ACK was not received in DDC2.
350 Macrovision Not Supported An IC supporting Macrovision has not been installed in the unit.
352 EDID Header Error Error in the EDID header.
353 EDID Check Sum Error EDID checksum error.
354 EDID Header & Check Sum Error Errors in both the EDID header and checksum.
355 User YPbPr Coefficient Error Error in the color difference coefficients.
358 Audio Data No. Error Error in the audio data number.
35A Audio Data File Not Found The audio data has not been registered.
35D Lip Sync Invalid EDID Latency
Error in the EDID at the connection destination (when Mode:EDID has
been selected with LipSync).
35F Lip Sync ‘EDID Port’ Error
The HDMI unit is not installed (when Mode:EDID has been selected
with LipSync).
360 Image License Error The image data license has not been supplied.
361 Data File Not Found
The data (other than the optional pattern and image data) cannot be
found.
362 Copy Condition Error
The copy source data and copy destination data are identical.
The number of copy source data and number of copy destination
data are different.
363 Image RAM Full There is not enough free space in the image memory.
Set the high-speed drawing mode in 9.1.16 to OFF or reduce the
number of data specified.
373 DP I2C NACK Error The response to AUX CH Read/Write is “I2C NACK”.
374 DP I2C Defer Error The response to AUX CH Read/Write is “I2C DEFER”.
375
eDP Power Under Volt Error
When pressing SIG ON key, the voltage value of external power
input is less than 1V.
376
eDP Changed Power Setting
When pressing SIG ON key, power control parameter tries to
change to the different program.
377
eDP Power Supply Control OFF When pressing SIG ON key, power control is OFF.