29
E
Initialization/Functional Restriction Setting (FUNCTION) menu
Function
Command Direction
Parameter Reply Control/Response contents
*
ALL RESET RSET W 0
-
ADJUSTMENT LOCK ALCK WR 0-2 0-2 0: OFF, 1:ON 1, 2:ON 2
º
OSD DISPLAY LOSD WR 0-2 0-2 0: ON 1, 1: OFF, 2: ON 2
º
LED OFLD WR 0-1 0-1 0: ON, 1: OFF
º
TEMPERATURE ALERT TALT WR 0-2 0-2 0: OFF, 1: OSD & LED, 2: LED
º
STATUS ALERT SALT WR 0-2 0-2 0: OFF, 1: OSD & LED, 2: LED
º
Others
Function
Command Direction
Parameter Reply Control/Response contents
*
VOLUME VOLM WR 0-31 0-31
º
BRIGHT VLMP WR 0-31 0-31
º
TEMPERATURE SENSOR DSTA R 0 Internal temperature normal
1 Internal temperature abnormal has occurred and the monitor is in standby
mode
2 Internal temperature abnormal occurred (To delete the information of
temperature abnormal, turn o the main power.)
3 Internal temperature abnormal has occurred and backlight brightness is
dimmed
4 Temperature sensor abnormal
TEMPERATURE ACQUISITION ERRT R Value Returns the temperature of the temperature sensor.
Indicates a temperature sensor abnormality when “126” is returned.
º
CAUSE OF LAST STANDBY MODE STCA W 0 Initialization
R 0 No detectable error has occurred
1 Standby mode by POWER button
2 Main power o by the main power switch
3 Standby mode by RS-232C
4 Input signal waiting mode by No Signal
6 Standby mode by abnormal temperature
20 Standby mode by OFF IF NO OPERATION setting
Controlling the Monitor with a PC (RS-232C)