AIO PUMP Q-Fan Control
Allows you to set AIO Pump fan control mode.
Conguration options: [Auto Detect] [DC Mode] [PWM Mode]
[Auto Detect] Detects the type of AIO Pump fan installed and automatically
switches the control modes.
[DC Mode] Enables the Q-Fan control in DC mode for 3-pin fan.
[PWM Mode] Enables the Q-Fan control in PWM mode for 4-pin fan.
AIO PUMP Profile
Allows you to select the appropriate performance level for AIO Pump fan.
Conguration options: [Standard] [Silent] [Turbo] [Full Speed] [Manual]
If AIO PUMP Prole is set to [Manual], we suggest raising your fan/pump duty to 100% if
your CPU temperature exceeds 75°C. Please be noted CPU performance will throttle due
to overheating with inefcient fan/pump duty.
The following items will not appear if you set AIO PUMP Prole to [Full Speed].
AIO PUMP Fan Q-Fan Source
AIO Pump fan will be controlled according to the selected temperature source.
Conguration options: [CPU] [MotherBoard] [VRM] [Chipset] [Multiple Sources]
The following items appear only when you set [AIO PUMP Fan Q-Fan Source] to [Multiple
Sources].
Temperature Source 1(~3)
These items allow you to select up to three temperature sources and AIO
Pump fan will automatically change based on the highest temperature.
Conguration options: [CPU] [MotherBoard] [VRM] [Chipset] [N/A]
AIO PUMP Step Up/Down
Allows you to set the value of AIO PUMP fan step up/down.
Conguration options: [0 sec] [12 sec] [25 sec] [51 sec] [76 sec] [102 sec] [127 sec]
[153 sec] [178 sec] [204 sec]
AIO PUMP Speed Low Limit
Allows you to set the lower speed limit for AIO PUMP fan. A warning message will
appear when the limit is reached. When set to [Ignore], no future warning message
will appear. Conguration options: [Ignore] [200 RPM] [300 RPM] [400 RPM] [500
RPM] [600 RPM]
The following items appear only when you set AIO PUMP Prole to [Manual].
Use the <+> and <-> keys to adjust the value or directly key in a desired value within
the valid range for each of the items below.
AIO PUMP Point4 Temperature
Allows you to set the AIO PUMP Point4 Temperature. Conguration options:
[60] – [100]
AIO PUMP Point4 Duty Cycle (%)
Allows you to set the AIO PUMP Point4 Duty Cycle. Conguration options:
[90] – [100]