EasyManua.ls Logo

Asus SABERTOOTH Z170 MARK 1 - Page 108

Asus SABERTOOTH Z170 MARK 1
176 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-44
Chapter 3: BIOS Setup
Chapter 3
Extension Fan 1-3 Upper Temperature [70]
Use the <+> or <-> keys to adjust the upper limit of the Extension Fan 1-3
temperature. The values range from 20 to 75.
Extension Fan 1-3 Max. Duty Cycle (%) [100]
Use the <+> or <-> keys to adjust the maximum Extension Fan 1-3 duty
cycle. The values range from 20% to 100%. When the CPU temperature
reaches the upper limit, the Extension Fan 1-3 will operate at the maximum
duty cycle.
Extension Fan 1-3 Middle Temperature [45]
Use the <+> or <-> keys to adjust the middle limit of the Extension Fan 1-3
temperature. The values range from 20 to 75.
Extension Fan 1-3 Middle. Duty Cycle (%) [60]
Use the <+> or <-> keys to adjust the maximum Extension Fan 1-3 duty
cycle. The values range from 20% to 100%. When the CPU temperature
reaches the upper limit, the Extension Fan 1-3 will operate at the maximum
duty cycle.
Extension Fan 1-3 Lower Temperature [40]
Use the <+> or <-> keys to adjust the lower limit of the Extension Fan 1-3
temperature. The values range from 20 to 75. The Extension Fan 1-3 will
operate at the minimum duty cycle when the temperature is lower than the
limit.
Extension Fan 1-3 Min. Duty Cycle(%) [60]
Use the <+> or <-> keys to adjust the minimum Extension Fan 1-3 duty
cycle. The values range from 0% to 100%. When the CPU temperature
is under the limit, the Extension Fan 1-3 will operate at the minimum duty
cycle.
Allow Fan Stop [Disabled]
This item allow the fan to run at 0% duty cycle when the temperature of the
source is dropped below the lower temperature.
Conguration options: [Disabled] [Enabled]
Water Pump Control [Disabled]
[Disabled] Disable the Water Pump control feature.
[DC mode] Enable the Water Pump control in DC mode for 3-pin chassis fan.
[PWM mode] Enable the Water Pump control in PWM mode for 4-pin chassis fan.
The following items appear only when you set the Water Pump Control to [DC mode] or
[PWM mode].
Water Pump Upper Temperature [70]
Use the <+> or <-> keys to adjust the upper limit of the Water Pump
temperature. The values range from 20 to 75.
Water Pump Max. Duty Cycle (%) [100]
Use the <+> or <-> keys to adjust the maximum Water Pump duty cycle.
The values range from 20% to 100%. When the CPU temperature reaches
the upper limit, the Water Pump will operate at the maximum duty cycle.
Water Pump Middle Temperature [45]
Use the <+> or <-> keys to adjust the middle limit of the Water Pump
temperature. The values range from 20 to 75.

Table of Contents

Other manuals for Asus SABERTOOTH Z170 MARK 1

Related product manuals