GB 13
INSTALLATION
Fitting
the extractor fan from the packaging and remove the 2 screws A
from the inner frame. You can now separate the inner frame from
the top part.
Hold the drilling template against the ceiling. Ensure that the arrow
is on the control panel side of the extractor fan.
Drill the connection holes with a diameter of 8 mm for fitting the
inner frame B in the ceiling.
Place suitable plugs in the drilled holes.
Do not place a screw at position X. Do place screws in the
remaining three holes. Do not tighten these screws completely.
Slide the inner frame B over the three screws.
Make a small turning movement so that the three screws fall into
the grooves.
Fasten the fourth screw X and tighten all screws.
Fasten the bottom part of the inner frame C to the top part B.
Adjust the desired height.
Fig.2