ERROR DESCRIPTION CAUSE CORRECTIVE ACTION:
Pump has no suction,
Pump is not building pressure
Air in filler hose
Bleed filler hose
Fig. 5.3
Fluid container empty
Exchange container
Fig. 5.3
Filler hose kinked
Remove kink
Exchange defective filler hose
03.9302-9003.3/740238
Pressure regulator turned off
Turn on pressure regulator all the
way
Set operating pressure
Fig. 5.9
Bleeder device cannot
be switched on
Power plug not plugged in
Plug in power plug
Fig. 5.2
Fuse defective The fuse must be exchanged
Pump runs without pumping
brake fluid
Filter screen is stopped up Clean filter screen
Operating pressure is set to 0 bar Set operating pressure correctly
Fig. 5.9