Direct mode Medium range
This configuration is used for direct mode at a maximum pressure of 1MPa (145 PSI).
Connection
Option / description
Regulator air
supply to
1
Connection of the regulator air supply to the filter input (1.2 MPa (174 PSI))
Air supply
to
2
Connection of the air supply (0.6 MPa (87 PSI))
Vacuum to
3
Connection to the vacuum (option)
4
to
5
Connection of the reference output to the reference part
6 to ATM
Output to be left to the atmosphere (exhaust of the part under test and the
reference part)
7
to
8
Connection of the test output to the part under test