- 22 -
2.4.1.2 Control panel with Qc2002™
controller
General description Qc2002™ control panel
A1 .......Qc2002™ display
F10......Fuse
The fuse trips when the current from the
battery to the engine control circuit exceeds
its setting. The fuse can be reset by pushing
the button.
H0 .......Panel light
S2 .......Emergency stop button
Push the button to stop the generator in case
of an emergency. When the button is
pressed, it must be unlocked, before the
generator can be restarted. The emergency
stop button can be secured in the locked
position with the key, to avoid unauthorized
use.
S20 .....ON/OFF switch
Position O: No voltage is supplied to the
Qc2002™ module, the generator will not
start.
Position I: Voltage is supplied to the
Qc2002™ module, it is possible to start up
the generator.
X25 .....Terminal strip
Qc2002™ Module
2.4.1.3 Control panel with Qc1103™
controller
A1 .......Qc1103™ display
F10......Thermal circuit breaker
The termal circuit breaker trips when the
current from the battery to the engine control
circuit exceeds its setting. It can be reset by
pushing the button.
G
Q2
N13
Q1
H0
S2
A1
S20
F10
L1L2
OFF
L1-N
L2L3 L2-N
L3L1
LL LN
L3-N
X25
v x.xx.xx