• Finally, check the basic functions and safety of the electronic unit in the TESTING and
INFORMATION submenus, see page 74 and 75. Check the function of the end switch and 95 °C
(55 °C for boilers DxxPX, PXxx) safety thermostat at the pellet inlet to the burner (contact of the
thermostat with the pipe), see page 10 and 11.
CAUTION - It is prohibited to do welding work on the equipment if the system is connected
to the electric mains and the electronic control unit is not removed. It might get damaged.
If the customer is not able to carry out the annual inspection and maintenance of the burner
by themselves, this service may be ordered from a service engineer. This service is subject
to a fee. Make a record of the annual maintenance and inspection in the operation manual
on page 92.