Long press
the
"
+
"
key to
go
to the security
protection
pagq
short
press
the
"M"
key, and the
voltage hundred digits ofthe overvoltage
automatic
power-off
barwill
flash, then short
press
the
" + "
or
"-"
keys to adjust the
value,
short
press
the
"M"
key again, the voltage
tens will flash
and can be adjusted. Continue with this
method, flashing the value ofthe over-current
power
column and can be adjusted, after the adjustment
is completed, long
press
the
"M"
keyto save
orflash to stop the system to automatically
save. The set
protection
threshold
value can be
increased by 5-10% according to
your
application
value, so as to ensure normal use and also
have
the
power-off protection
function
(the
set
protection
value will also run in the background
of other interfaces). When the input voltage orthe
power
value ofthe current flow exceeds the
threshold
you
se( the
qystem
will instantly cut off the
power
and use the
horn to
prompt
and
at the same time display
an alarm message on the display for
you
to check.
At this time, if the
user's button signal or
infrared remote
control
signal is not received, the
product will continue
to
power
off. Until the user releases the danger
and
presses
any key or remote control key on
the host the system will return to the
protection
interface
and
automatically be in the off state,
waiting for
the userto
reset or restart the
power
Long
press
the
"+"
button to
go
to the smart
power-off
category
A
page
and
select the
"on"
state, observe
and record the charging
power
value ofthe charged device once
after it is fully
charged; Then, add
2-5W on the basis ofthis
value, which is the
powervalue
of
how many
watts ofyour full automatic
power-off
setting
is less than the continuous value and
turn
on
the
"auto"
gear
In this way,
when the
system
detects that the current
power
value is less than
the
powervalue you
set and continues
forthe recharge time
you
set, the system
displays the
power-off
icon and cuts
offthe
power
output
thereby
protecting your
device(Ihe
longerthe
duration
you
set, the
longer the subsequent charging
time is when it is fully charged,
so as to
ensure that the device can be
fuliy charged and at the
same time double-monitoring to
achieve
accurate and automatic
power.offfor
safe charging
protection).
Tips for viewing the
progress
bar and
countdown in the lower riglrt comer
of the display
intedace:
When the system detects that the
measured
powervalue
is less than the
powervalue you
set
the system starts counting down, and the
progress
bar is calculated according to
the duration
ratio
you
set
The
progress
bar decreases and changes
colorfrom
yellow
to
red
until the
end of
the
power
failure.
When the
powervalue
measured by
the system is
greaterthan
the
power
value
you
set
at a ceftain moment, the countdown
will be cleared immediately,
and the
progress
barwill
fill up instantly, and then a
new round of detection will be
performed.
Long
press
the
"+ "
button
to
go
to the smart
power-off
type B
page
and seiect
the
"on"
state.
Observe and record
the minimum
power value
of
the connected device when
it is
powered
on.
Then, subtract 5-25W on
the basis ofthis value.
This is how many watts of
power
should
be set
foryour connection and turn
it on to the
'auto"
gear:
In this way, when the system detects
that
the current
power
value
is
greater
than the
power value
you
se!, it willjudge that
your
device
has
been
powered
on. At this time,
the system starts to count down to the
duration value
you
set, and the system determines
that
you
may
have forgotten to turn offthe device
because
you
left home and automatically
cut offthe
powet
so as
to achieve the
purpose
of
people
- 3
-