– Connect hand pump for gear oil - VAS 6617- with -VAS
6617/1- and -VAS 6617/12- at ATF inspection and filler hole.
Caution
Risk of damage to gearbox if ATF and gear oil (MTF) mix via
shared breather opening.
♦ Do not fill with more than 0.5 ltr. of ATF.
– Use hand pump to fill gearbox with 0.5 ltr. of ATF.
– Repeat entire work sequence for “Checking ATF level”.
Attaching
Note
The ATF inspection and filler hole must be closed again before
the ATF reaches a temperature of 45 °C.
– Tighten plug for inspection and filler hole or close plug by in‐
serting it all the way (depending on type of plug). The ATF level
check is now completed.
Tightening torques
♦ Screw plug ⇒ Item 1 (page 83)
♦ ⇒ General body repairs, exterior; Rep. gr. 66 ; Noise insula‐
tion; Exploded view - noise insulation
9.2 Draining and filling ATF
Note
♦
The 7-speed dual clutch gearbox has an ATF section and an
MTF section.
♦
The ATF is in the blue section of the gearbox and can be
drained off via the ATF drain plug -1- and added via the ATF
filler plug -2-.
♦
The MTF is in the green section of the gearbox and can be
drained off by removing the MTF pump -4- and added via the
MTF inspection plug -3-.
♦
The bolt securing the gear cluster -arrow- is not a drain plug!
Special tools and workshop equipment required
♦ Vehicle diagnostic tester
Audi A4 2015 ➤ , Audi A4 Avant 2015 ➤ , Audi A4 China 2016 ➤ , Audi A4 a ...
7-speed dual clutch gearbox 0CJ, 0CK, 0CL, 0DN, 0DP - Edition 08.2018
94 Rep. gr.34 - Controls, housing