Actuation of analog displays
-> Readout on VAS 5051:
A - 1st control element in test
1 - Analog displays
The following tests are implemented simultaneously:
◆ Passage of coolant temperature gauge needle through entire display range
◆ Passage of rev counter needle through entire display range
◆ Passage of speedometer needle through entire display range
◆ Passage of fuel gauge needle through entire display range
The following fixed values are displayed on completion of the above process:
Coolant temperature gauge: 90 °C
Rev counter: 3000 rpm
Speedometer: 100 km/h
Fuel gauge: 1/2
Actuation of warning lamp test for dash panel insert
- Touch ▸ key.
-> Readout on VAS 5051:
A - 2nd control element in test
2 - Dash panel insert warning lamp test
◆ Warning lamps in dash panel insert are actuated