900- Electric and Data Acquisition
Version 1 2016-01-01 91 / 113
d) Calibration and adjustment
Various elementary functions can or must be adjusted and/or calibrated. For
example, the following variables must be recalibrated after every engine or ECU
change:
- Throttle pedal (aps) via CWAPSADJ
(also if throttle pedal changed)
- Butterflies (ath) via CWTHRADJ
(also if one or both throttles changed)
- Camshaft (cam) via CWCAMADAP
(also if a camshaft sensor changed)
Other variables to calibrate:
- Clutch paddles (aps) left and right via CWCLPADDLExADJ
(also if steering wheel changed)
- Steering angle sensor CWSTEERCAL
- Damper travel (if available) CWDAMCAL
Attention
No error entries for the relevant interface may appear: E_xxx = FALSE.