Place used oil collection and extraction unit -V.A.G 1782- be‐
low gearbox.
Remove bolt securing flange shaft (right-side). To do so, screw
two bolts into flange and counterhold flange shaft with suitable
lever.
Pull out flange shaft together with spring, thrust washer and
tapered ring.
Installing
Tightening torque ⇒ page 93 , ⇒ page 93 .
Installation is carried out in reverse sequence; note the following:
Push flange shaft in against spring pressure securing bolt.
Install drive shaft (right-side) ⇒ Rep. Gr. 40 .
Check gear oil level and top up as required ⇒ page 66 .
1.3 Renewing oil seal for flange shaft (left-
side)
Special tools and workshop equipment required
Thrust piece -3305-
Extractor tool -T20143-
Removing
Proceed as follows:
Note
The oil seal can be renewed with the gearbox installed.
Observe general repair instructions ⇒ page 8 .
Observe rules for cleanliness when working on the gearbox
⇒ page 10 .
Audi TT 2007 ➤
Direct shift gearbox 02E, front-wheel drive - Edition 12.2006
1. Flange shafts and oil seals - exploded view 97