Installation & Maintenance Manual 220 Document #: LTRT-40111
Mediant 1000B SBA
30.2 Upgrading or Recovering with Monitoring
You can monitor the SBA upgrade and recovery process for the OSN3B and OSN4 server
using an HDMI monitor (via the Micro HDMI port).
Notes:
• This procedure is relevant for the OSN3B and OSN4 server only.
• This procedure describes how to connect to the OSN3B and OSN4 using a monitor
(via the Micro HDMI port).
To connect to the OSN3B and OSN4 server:
1. Open (using a text editor such as Notepad) the RecoveryUtil.ini file and then do the
following:
• Set the 'RecoveryStartType' parameter to 0, in order to start the process
automatically when Windows PE starts.
• Set the 'OnExit' parameter to 2 so that the OSN server shuts down upon SBA
upgrade and recovery completion.
[Execution] RecoveryStartType= 0
[Execution] OnExit = 2
2. Save and close the RecoveryUtil.ini file.
3. Connect the USB hub into the USB hub port on the OSN3B and OSN4 server.
4. Plug the USB dongle into a USB hub connector.
5. Plug the mouse and keyboard into respective connectors on the USB hub.
6. Using the supplied MINI HDMI TO HDMI 1.5m cable, connect the Micro HDMI port on
the OSN3B or OSN4 module using a Mini HDMI connector and connect the other end
to the HDMI port on the monitor using a Type-D male connector. For HDMI connector
cable pinouts (see Section 5.1.4).
Figure 30-4: Plugging OSN Server Accessories
7. Power off and then power on the Mediant 1000B to reboot the OSN server; the SBA
Upgrade and Recovery process starts and logged messages are displayed on the