Installation & Maintenance Manual 34 Document #: LTRT-40111
Mediant 1000B SBA
Item Label Color State Description
6
Blue Flashing Module undergoing shutdown sequence when
module pulled out to first extraction position.
On Module shutdown sequence complete and the
module can be extracted from the chassis slot.
Off Module correctly inserted in chassis slot.
7
Red On Hardware failure (supplied voltage is not within
normal operating range ensure CRMX is
installed in chassis).
Flashing Upgrade in progress.
- Off Normal operation.
8 SPEED Green On 100Base-TX connection.
Yellow On 1000Base-T connection.
- Off 10Base-T connection if ACT LED active.
9 ACT Green On Valid Ethernet link (cable connection) has been
established.
- Off The LED goes temporarily off if network packets
are sent or received. When this LED remains off, a
valid link has not been established due to a
missing or a faulty cable connection.