10.1.2 Initially Connecting to the SBA Using the External NIC
When you initially connect to the SBA using the external NIC, the network cable should be
connected to Ethernet port 1 on the OSN module.
The SBA Management Interface is initially accessed using the pre-configured factory
default IP address of the OSN server (192.168.0.20/16). You can then use the SBA
Management interface to change this default IP address to suit your network environment.
To initially connect to the SBA using the external NIC:
1. Using a network cable, connect the PC to the appropriate Ethernet port:
On the OSN3B/OSN4 module, connect to Port 1:
Figure 10-7: Connecting to LAN Port on OSN3B/OSN4 Module (Rear Panel View)
On the OSN3 module, connect to the port labeled :
Figure 10-8: Connecting to LAN Port on OSN3 Module (Rear Panel View)
2. Change your computer’s IP address so that it is in the same subnet as the default IP
address of the OSN server hosting the SBA.
3. Open a standard Web browser (Firefox, Google Chrome, or Internet Explorer 9 and
later is recommended), and then in the URL address field, enter the OSN server
default IP address (192.168.0.20/16).