User's Manual 65. Configuration Parameters Reference
Parameter Description
management platforms:
SNMP (restores default users and retains other
configured users):
1) Set acSysGenericINILine to
WEBPasswordControlViaSNMP = 1, and reset the
device with a flash burn (set
acSysActionSetResetControl to 1 and
acSysActionSetReset to 1).
2) Change the username and password in the
acSysWEBAccessEntry table. Use the following
format:
Username acSysWEBAccessUserName:
old/pass/new
Password acSysWEBAccessUserCode:
username/old/new
Customizing Web GUI
[WelcomeMessage]
configure system > welcome-
msg
Defines a welcome message displayed on the Web
interface's Web Login page.
The format of the ini file table parameter is:
[WelcomeMessage ]
FORMAT WelcomeMessage_Index =
WelcomeMessage_Text
[\WelcomeMessage]
For Example:
FORMAT WelcomeMessage_Index =
WelcomeMessage_Text
WelcomeMessage 1 = "**********************************" ;
WelcomeMessage 2 = "********* This is a Welcome
message ***" ;
WelcomeMessage 3 = "**********************************" ;
For more information, see Creating a Login Welcome
Message on page 71.
Note:
Each index row represents a line of text. Up to 20 lines
(or rows) of text can be defined.
The configured text message must be enclosed in
double quotation marks (i.e., "...").
If the parameter is not configured, no Welcome message
is displayed.
[UseProductName] Enables the option to customize the name of the device
(product) that appears in the management interfaces.
[0] = Disabled (default).
[1] = Enables the display of a user-defined name, which
is configured by the UserProductName parameter.
For more information, see Customizing the Product Name
on page 69.
[UserProductName] Defines a name for the device instead of the default name.
The value can be a string of up to 29 characters.
For more information, see Customizing the Product Name