CHAPTER40 Automatic Provisioning
Mediant 4000 SBC | User's Manual
c. Automatic Update of Call Progress Tone file:
ini File:
CptFileURL = 'https://www.company.com/call_progress.dat'
CLI:
# configure system
(config-system)# automatic update
(automatic-update)# call-progress-tones 'http://www.company.com/call_
progress.dat'
d. Automatic Update of ini configuration file:
ini File:
IniFileURL = 'https://www.company.com/config.ini'
CLI:
# configure system
(config-system)# automatic update
(automatic-update)# voice-configuration
'http://www.company.com/config.ini'
e. Enable Cyclical Redundancy Check (CRC) on downloaded ini file:
ini File:
AUPDCheckIfIniChanged = 1
CLI:
# configure system
(config-system)# automatic update
(automatic-update)# crc-check regular
4. Power down and then power up the device.
Automatic Update from Remote Servers
This example describes how to configure the Automatic Update feature where files are stored and
downloaded from different file server types. The example scenario includes the following:
FTPS server at ftpserver.corp.com for storing the License Key file. The login credentials to the
server are username "root" and password "wheel".
HTTP server at www.company.com for storing the configuration file.
DNS server at 80.179.52.100 for resolving the domain names of the provisioning servers
(FTPS and HTTP).
To set up Automatic Provisioning for files stored on different server types (example):
1. License Key file:
a. Set up an FTPS server and copy the License Key file to the server.
b. Configure the device with the URL path of the License Key file:
ini File: