Version 6.2 791 February 2011
SIP User's Manual 12. Configuration Parameters Reference
Parameter Description
[CASTablesNum]
Indicates how many CAS protocol configurations files are
loaded.
The valid range is 1 to 8.
Note: For this parameter to take effect, a device reset is
required.
CAS State Machines Parameters
Note: For configuring the 'CAS State Machine' table using the Web interface, see ''Configuring CAS
State Machines'' on page 99.
Web: Generate Digit On Time
[CASStateMachineGenerateDigit
OnTime]
Generates digit on-time (in msec).
The value must be a positive value. The default value is -1.
Web: Generate Inter Digit Time
[CASStateMachineGenerateInter
DigitTime]
Generates digit off-time (in msec).
The value must be a positive value. The default value is -1.
Web: DTMF Max Detection Time
[CASStateMachineDTMFMaxOn
DetectionTime]
Detects digit maximum on time (according to DSP detection
information event) in msec units.
The value must be a positive value. The default value is -1.
Web: DTMF Min Detection Time
[CASStateMachineDTMFMinOnD
etectionTime]
Detects digit minimum on time (according to DSP detection
information event) in msec units. The digit time length must be
longer than this value to receive a detection. Any number may
be used, but the value must be less than
CasStateMachineDTMFMaxOnDetectionTime.
The value must be a positive value. The default value is -1.
Web: MAX Incoming Address
Digits
[CASStateMachineMaxNumOfInc
omingAddressDigits]
Defines the limitation for the maximum address digits that need
to be collected. After reaching this number of digits, the
collection of address digits is stopped.
The value must be an integer. The default value is -1.
Web: MAX Incoming ANI Digits
[CASStateMachineMaxNumOfInc
omingANIDigits]
Defines the limitation for the maximum ANI digits that need to
be collected. After reaching this number of digits, the collection
of ANI digits is stopped.
The value must be an integer. The default value is -1.
Web: Collect ANI
[CASStateMachineCollectANI]
In some cases, when the state machine handles the ANI
collection (not related to MFCR2), you can control the state
machine to collect ANI or discard ANI.
[0] No = Don't collect ANI.
[1] Yes = Collect ANI.
[-1] Default = Default value.
Web: Digit Signaling System
[CASStateMachineDigitSignaling
System]
Defines which Signaling System to use in both directions
(detection\generation).
[0] DTMF = Uses DTMF signaling.
[1] MF = Uses MF signaling (default).
[-1] Default = Default value.