7. Mounting positions of the local controls
The mounting position of the local controls is designed according to the
order. If, after mounting the actuator to the valve or the gearbox on site, the
local controls is in an unfavourable position, the mounting position can eas
-
ily be changed at a later date.
Four mounting positions are possible:
Changing the mounting position
.
Disconnect actuator from the mains before opening.
.
Turn local controls by a maximum of 180°!
.
Ensure that the wires are neither twisted nor jammed.
.
Loosen 4 bolts and remove the local controls.
.
Turn local controls in one of the four positions and re-place on the actuator.
.
Clean sealing faces of housing and cover.
.
Check whether O-ring is in good condition.
.
Replace cover on switch compartment and fasten bolts evenly crosswise.
13
Multi-turn actuators SA 07.1 – SA 30.1/SAR 07.1 – SAR 30.1
Operation instructions with actuator controls AUMA MATIC AM 01.1/AM 02.1
Figure 7: Mounting position A
Actuator
Figure 8: Mounting position B
Actuator
Figure 9: Mounting position C
Actuator
Figure 10: Mounting position D
Actuator