4. Apply a thin film of non-acidic grease (e.g. petroleum jelly) to the O-ring and
insert it correctly.
Figure 89:
Flameproof enclosure, danger of explosion!
Risk of death or serious injury.
Handle cover and housing parts with care.
Joint surfaces must not be damaged or soiled in any way.
Do not jam cover during fitting.
5. Place cover [1] on switch compartment.
6. Fasten screws [2] evenly crosswise.
74
SAEx 07.2 SAEx 16.2/SAREx 07.2 SAREx 16.2 Control unit - electromechanical