A8 - Configuration Menu
PAIR 2.0 DIP
PAIR 2.0
PAIR 2.0 DIP
The PAIR 2.0 DIP procedure uses DIP setting in the receiving unit; this aims at defining the beginning and end of the proce-
dure. This way the possibility of pairing the unit with an undesired receiving unit is avoided.
To perform the PAIR 2.0 DIP procedure, do the following:
1. Remove power from the receiving unit and wait until the POWER LED switches off.
2. Open the receiving unit and set DIP switch 2 on the mother board to ON.
3. Close the receiving unit and power it (POWER LED on).
4. Within 2 minutes after powering the receiving unit, perform the following actions with the transmitting unit unpaired and
switched off, and the STOP pushbutton not activated.
5. Remove power from the receiving unit and wait until the POWER LED switches off.
6. Open the receiving unit and set DIP switch 2 on the mother board to OFF.
7. Close the receiving unit.
8. Make sure that the transmitting unit is paired with the desired receiving unit (see page9).
ON
21
Receiving unit
DIP
ON
21
1
2
34
R
G
STOP
S1 S2
1
2
34
R
G
STOP
S1 S2
1
2
34
R
G
STOP
S1 S2
PAIR
1
R
1
R
1
R
STARTFUNCT.STARTFUNCT.STARTFUNCT.
2
3
4
G 2
3
4
G 2
3
4
G
Keep pushbutton START
pressed until the red LED is
steady on and the green
LED blinks.
Perform the UNPAIR proce-
dure if this signal does not
appear.
Keep pushbuttons FUNCTION,
START and S1 pressed until the
ENABLE LED (receiving unit)
and the green LED (transmitting
unit) illuminate
Keep pushbuttons
FUNCTION, START and
S2 pressed until the green
LED is steady on to save
this setting
Receiving unit powered on. Transmitting unit off STOP pushbutton releasedTransmitting unit unpaired
ON
21