LIIBKU00E1-02.fm 5 AUTEC - Air Series
A8 - Configuration Menu
PAIR 2.0 SERIAL
PAIR 2.0
PAIR 2.0 SERIAL
The PAIR 2.0 SERIAL procedure saves in the transmitting unit the “SERIAL N.” of the receiving unit you want to pair. This way
the possibility of pairing the unit with an undesired receiving unit is avoided, without the need to open the receiving unit.
The pairing may occur even when the transmitting unit is placed in enclosed spaces or is out of sight (e.g. the trans-
mitting unit and receiving unit are not in the same working environment or are separated by walls). Therefore, do not
perform this procedure if the receiving unit is out of sight, as it is important to follow the correctness of the paring
step by step.
Pay particular attention when entering the “SERIAL N.”.
If a wrong “SERIAL N.” is entered, the transmitting unit may get paired with an undesired receiving unit if this is in
its working range (even though the pairing in this case has very low probabilities to happen).
To perform the PAIR 2.0 SERIAL procedure, do the following:
1. Note down the “SERIAL N.” corresponding to the receiving unit you want to use for the PAIR procedure (see page 6).
2. Save the number (excluding the first two letters) that forms the "SERIAL N." in the transmitting unit (see page 6).
3. Make sure that the number is correct (see page 7).
4. Pair the transmitting unit with the desired receiving unit (see page 8).
5. Make sure that the transmitting unit is paired with the desired receiving unit (see page9)
.