C2 Series User Manual Rev. 1.9
2) Configuration with two AOIs, two DCs, disabled NDR mode and output of 5 profiles resulting to a
frame height of 20 rows:
ProfilesPerFrame = 5
NumAOIs = 2
EnableDC0 = true
EnableDC1 = false
EnableDC2 = true
NDRMode = ”Off”
Row #
Description
Profile #
1
Data of DC0 readout from AOI1
1
2
Data of DC2 readout from AOI1
3
Data of DC0 readout from AOI2
4
Data of DC2 readout from AOI2
5
Data of DC0 readout from AOI1
2
6
Data of DC2 readout from AOI1
7
Data of DC0 readout from AOI2
8
Data of DC2 readout from AOI2
9
Data of DC0 readout from AOI1
3
10
Data of DC2 readout from AOI1
11
Data of DC0 readout from AOI2
12
Data of DC2 readout from AOI2
13
Data of DC0 readout from AOI1
4
14
Data of DC2 readout from AOI1
15
Data of DC0 readout from AOI2
16
Data of DC2 readout from AOI2
17
Data of DC0 readout from AOI1
5
18
Data of DC2 readout from AOI1
19
Data of DC0 readout from AOI2
20
Data of DC2 readout from AOI2