Chapter 4: AC Drive Parameters
4–36
Multi-Function Output Terminal 1 (Relay Output) Default Setting: 00
Multi-Function Output Terminal 2 (DO1) Default Setting: 01
Multi-Function Output Terminal 3 (DO2) Default Setting: 02
Multi-Function Output Terminal 4 (DO3) Default Setting: 03
Settings for P3.11 - P3.14:
00 AC Drive Running
01 AC Drive Fault
02 At Speed
03 Zero Speed
04 Above Desired Frequency (P3.16)
05 Below Desired Frequency (P3.16)
06 At Maximum Speed (P0.02)
07 Over Torque Detected
08 Above Desired Current (P3.17)
09 Below Desired Current (P3.17)
10 PID Deviation Alarm (P3.18 and P3.19)
11 Heatsink Overheat Warning (OH)
12 Soft Braking Signal
13 Above Desired Frequency 2 (P3.20)
14 Below Desired Frequency 2 (P3.20)
15 Encoder Loss
*16 PID Feedback Loss Warning
* - Parameter setting available only with firmware v1.04 or higher (refer to P9.39)
GS3-xxxx
R1O
R1
R1C
AC
~
LOAD
LOAD
OR
+–
Wiring Diagram for
R1, R1C, R1O
(Relay Output)
GS3-xxxx
DO1
DO2
DO3
DOC
Digital Output Com.
LOAD
LOAD
+–
LOAD
Wiring Diagram for
DO1, DO2, DO3, DOC
(Digital Outputs)
P3.14
P3.13
P3.12
P3.11
DURAPULSE AC Drive User Manual