Chapter 5: DURAPULSE MODBUS Communications
5–46
DL MRX/MWX Communication Program (continued)
(Continued next page)
17
Drive #1 Speed Control
bit 60/30Hz
X3
K300
LD
BIN
Drive #1
Speed Ref New
V3000
OUT
18
K600
LD
BIN
Drive #1
Speed Ref New
V3000
OUT
Drive #1 Speed Control
bit 60/30Hz
X3
19
K1
LD
Drive #1
Run CMD New
V3001
OUT
Drive #1 Run/Stop
X5
20
K0
LD
Drive #1
Run CMD New
V3001
OUT
Drive #1 Run/Stop
X5
Rungs 17 & 18 select either 30Hz or 60Hz based on X3.
Rungs 19 & 20 select Run or Stop based on X5.
DURAPULSE AC Drive User Manual