LCD Timer(Touch Type)
T = Setting time, T > Ta, Rt = Reset time
LE4SA Output operation mode
※
Initial status : UP mode-display value is "0", output is "OFF". DOWN mode-display value is "setting time", output is "OFF".
※
Instantaneous contact(OUT2) will be returned when power is off.
※
RESET key is locked for default set and release the lock to use.
Mode Time chart Operation
[
OND
]
POWER
※
RESET
Time limit contact
(
⑧
-
⑥
)
Instantaneous contact
(
①
-
③
)
Set time
Set time
0
0
UP
DOWN
T T TRt
T
POWER
Time limit
contact
output
OND
ON Delay
1. Timing operation starts when power is ON.
2. Time limit output will be ON when timing operation is progressed up to the setting time. Display value will be
HOLD.
3. If selecting time limit 1c + instantaneous 1c mode, instantaneous output will be ON when power is ON and goes
OFF when power is OFF.
4. If pressing RESET key, display value and time limit output will be reset.
[
ONd2
]
POWER
※
RESET
Time limit contact
(
⑧
-
⑥
)
Instantaneous contact
(
①
-
③
)
Set time
Set time
0
0
UP
DOWN
T T TRt
T
Tout
POWER
Time limit
contact
output
OND
Ⅱ
ON Delay 2
(One-shot output)
1. Timing operation starts when power is ON.
2. Time limit output will be ON during Tout setting time and goes OFF when timing operation is progressed up to
the setting time. Display value will be HOLD.
3. If selecting time limit 1c + instantaneous 1c mode, instantaneous output will be ON when power is ON and goes
OFF when power is OFF.
4. If pressing RESET key, display value and time limit output will be reset.
5. Tout setting range: 0.01 sec to 99.99 sec.
[
FLK
]
POWER
※
RESET
Time limit contact
(
⑧
-
⑥
)
Instantaneous contact
(
①
-
③
)
Toff
Ton
Toff
Ton
0
0
UP
DOWN
RtToff Toff Toff ToffToff Ton Ton Ton TonTa
Toff
Toff
Ton
Ton
POWER
Time limit
contact
output
FK
Flicker
(Toff operation
precedes)
1. Control output will be repeatedly OFF during Toff setting time and will be ON during Ton setting time when
power is ON.
2. If selecting time limit 1c + instantaneous 1c mode, instantaneous output will be ON when power is ON and goes
OFF when power is OFF.
3. If pressing RESET key, display value and time limit output will be reset.
4. It is able to set each Toff time and Ton time separately. In [
] mode, timing operation starts with Toff.
[
FLk1
]
POWER
※
RESET
Time limit contact
(
⑧
-
⑥
)
Instantaneous contact
(
①
-
③
)
Toff
Ton
Toff
Ton
0
0
UP
DOWN
RtToff Ton Toff ToffToffTon Ton Ton TonTa
Toff ToffTon
Ton
POWER
Time limit
contact
output
FK
Ⅰ
Flicker 1
(Ton operation
precedes)
1. Control output will be repeatedly ON during Ton setting time and will be OFF during Toff setting time when
power is ON.
2. If selecting time limit 1c + instantaneous 1c mode, instantaneous output will be ON when power is ON and goes
OFF when power is OFF.
3. If pressing RESET key, display value and time limit output will be reset.
4. It is able to set each Ton time and Toff time separately. In [
] mode, timing operation starts with Ton.
Ton, Toff > Ta
Tout = output time
T = set time
T = set time
Ton, Toff = set time
Enables to set Ton and
Toff time differently.
Ton, Toff = set time
Enables to set Ton and
Toff time differently.