Input type Decimal point Display Input range(℃) Input range(℉)
Thermocouple
K (CA)
1 KCA.H -50 to 1200 -58 to 2192
0.1 KCA.L -50.0 to 999.9 -58.0 to 999.9
J (IC)
1 JIC.H -30 to 800 -22 to 1472
0.1 JICL -30.0 to 800.0 -22.0 to 999.9
L (IC)
1 LI.H -40 to 800 -40 to 1472
0.1 LIC.L -40.0 to 800.0 40.0 to 999.9
T (CC)
1 TCC.H -50 to 400 -58 to 752
0.1 TCC.L -50.0 to 400.0 -58.0 to 752.0
R (PR) 1 RPR 0 to 1700 32 to 3092
S (PR) 1 5PR 0 to 1700 32 to 3092
RTD
DPt 100Ω
1 DPt.H -100 to 400 -148 to 752
0.1 DPt.L -100.0 to 400.0 -148.0 to 752.0
Cu50Ω
1 CU5.H -50 to 200 -58 to 392
0.1 CU5.L -50.0 to 200.0 -58.0 to 392.0