Loading...
Power consumption Max. 8VA
Display method
11-segments (PV: white, SV: green), other display
(yellow) with LCD method1
Character size
PV(W×H) 7.2×14mm 10.7×17.3mm 7.2×15.8mm 16×26.8mm
SV(W×H) 3.9×7.6mm 6.8×11mm 6.2×13.7mm 10.7×17.8mm
Input type
RTD DPt100Ω, Cu50Ω (permissible line resistance max. 5Ω)
TC K (CA), J (IC), L (IC), T (CC), R (PR), S(PR)
Display accuracy2
RTD
At room temperature: (23±5): (PV ±0.3% or
±1, select the higher one) ±1-digit
Out of room temperature: (PV ±0.5% or ±2,
select the higher one) ±1-digit
TC
Control output
Relay 250VAC 3A, 30VDC 3A, 1a
SSR
Max. 12VDC
±2V 20mA
Max. 13VDC ±3V 20mA
Current DC4-20mA or DC0-20mA (load resistance max. 500Ω)
Option output
Alarm
output
AL1, AL2: 250VAC 3A , 30VDC 3A 1a
Trans.
output
DC4-20mA (load resistance max. 500Ω, output
accuracy: ±0.3%F.S.)
Com.
output
RS485 communication output (Modbus RTU method)
Control method ON/OFF control, P, PI, PD, PID control
Hysteresis 1 to 100/ (0.1 to 50.0/) variable