Specifications
Hydrostatic Test Pressure...............................................................................................................................300 psi (20.69 bar)
Working Pressure................................................................................................................................20-127 psi (1.38-8.76 bar)
Standard 12 Volt Transformer Input Electrical Rating.................................................................................................115V 60Hz
Optional 12 Volt Transformer Input Electrical Rating........................................................................... 115V 50 Hz, 230V 50 Hz,
230V 60 HZ, 100V 60Hz, 100V 50 HZ
Transformer Cord.........................................................................................................................................120 inch (1.5m) long
Pressure Tank Thread .......................................................................................................................................2 1/2 inch 8 male
Brine Line Thread............................................................................................................................................1/4 inch NPT male
Distributor Tube Diameter Required ............................................................................................................13/16 OD (20.6 mm)
Distributor Tube Length ............................................................................ 1 1/4 inch (31.8 mm) higher than top of mineral tank
Standard Manifold Connection.............................................................................3/4-inch NPT inlet-outlet, 3/8-inch NPT drain
Optional Manifold Connection.................................................................................1-inch NPT inlet-outlet, 1/2-inch NPT drain
3/4-inch BSPT inlet-outlet, 3/8-inch BSPT drain
1-inch BSPT inlet-outlet, 1/2-inch BSPT drain
Optional Bypass Valve...............................3/4-inch (19.1 mm) or 1-inch (25.4 mm) copper tailpiece, 1/2-inch NPT male drain
Control Module, Tank Adapter, Optional Bypass Valve .................................................................................Reinforced NORYL
Inlet-Outlet Manifold .........................................................................................................................Brass or reinforced NORYL
Rubber Goods ....................................................................................................................Compounded for cold water service
Brine Refill Control...........................................................1 to 10 lbs (0.45 to 4.5 kg) of salt or 3 to 19 lbs (1.3 to 8.6 kg) of salt
Injector Size “A” White..............................................Nozzle .042 inch (1.1 mm) Diameter, Throat .089 inch (2.3 mm) Diameter
Injector Size “B” Blue ...............................................Nozzle .052 inch (1.3 mm) Diameter, Throat .099 inch (2.5 mm) Diameter
Injector Size “C” Red................................................Nozzle .059 inch (1.5 mm) Diameter, Throat .099 inch (2.5 mm) Diameter
Backwash Controllers Available for ...............................................................................................6, 7, 8, 9, 10, 12, 13, 14 inch
(15.2, 17.8, 20.3, 22.9, 25.4, 30.5, 33.0, 35.6 cm) diameter mineral tanks.
All are sized to flow 4.5 gpm/sq ft (183 L/m/m
2
) of bed area.
Shown with optional i-lid cover PN 1000062.