FUNCTION KEYS
7.
NOTE: Normally, the 2nd funcon of a key needs to be pressed down for > 3 sec. to be acvated.
KEY MODE
PUSH
TIME
DEFINITION
Weighing, Counng,
or Percent Mode
<3 Seconds
Enters or Exits HOLD Mode
>3 Seconds
Enters SETUP Mode
Input Data Mode
<3 Seconds
Returns to last sub-menu
>3 Seconds
Inputs Decimal Point
Menu Selecon Mode
Returns to last sub-menu
Weighing, Counng,
or Percent Mode
<3 Seconds
Sends output data via the serial port
>3 Seconds
Selects Mode: Weighing, Counng, or Percent
Input Data Mode
Increases the digit in the ashing data entry
posion by 1
Menu Selecon Mode
Returns to last item of current sub-menu
Weighing, Counng,
or Percent Mode
<3 Seconds
Adds accumulaon values to memory;
displays instances and totals
>3 Seconds
Displays accumulaon instances and totals
Input Data Mode
Decreases the digit in the ashing data entry
posion by 1
Menu Selecon Mode
Goes to the next item of current sub-menu
Weighing Mode <3 Seconds
Changes weighing unit of measure
Counng or Percent
Mode
<3 Seconds
Enters the submenu to input piece weight for
counng or to enter reference weight for
percent-weighing
Weighing, Counng,
or Percent Mode
>3 Seconds
Enters the submenu to input the comparave
data range for check-weighing
Time or Date Mode >3 Seconds
Enters me or date seng mode
Input Data Mode
Shis the ashing data entry posion from
right to le
Menu Selecon Mode
Goes to next item of current sub-menu
Weighing, Counng,
or Percent Mode
<3 Seconds
Tare the weight
>3 Seconds
Enters pre-determined tare input mode
Input Data Mode
Conrms the input data and forwards to next step
Menu Selecon Mode
Conrms the input data and forwards to next step
Power O
Powers on
Weighing, Counng,
or Percent Mode
<3 Seconds
Zeros the plaorm weight
>3 Seconds
Powers o
Input Data Mode
Ignores the modicaon
Menu Selecon Mode
Exits from current working mode
PRINT
FUNC
ACC
TOTAL
UNIT
DATA
TARE
PRESET
HOLD
SETUP
ZERO
ON/OFF