EasyManua.ls Logo

Avaya 1600 Series - Chapter 4: Avaya Aura Communication Manager Administration; Call Server Requirements; Switch Compatibility and Aliasing IP Telephones

Avaya 1600 Series
99 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
H323 Telephone Installation Page 31
Issue 23e (Friday, February 15, 2019)IP Office™ Platform 11.0
Comments on this document? infodev@avaya.com
Installation: System H.323 Support
2. Select System.
3. Select the Telephony tab and then the Telephony sub-tab.
4. Locate the RTCP Collector Configuration section.
·
Send RTCP to an RTCP Collector
Enable system RTCP reporting.
·
Server Address
Sets the address of the third-party QoS monitoring application to which the system sends RTCP reports.
·
UDP Port Number
Sets the destination port. The default is 5005.
·
RTCP reporting interval
Sets how frequently the system sends RTCP reports.
5. If these setting needed changing, save the configuration back to the system.
2.2.3.3 Setting the Quality Alarm Levels
The system can send call quality alarms to the System Status Application. It can also send the same alarms to SNMP,
emails or Syslog destinations. For details of how to configure these refer to the IP Office Manager documentation. The
settings below are used to set the levels which, if exceeded, cause an alarm to be sent at the end of a call.
To set the Quality of Service alarm levels:
1. Using IP Office Manager, retrieve the configuration from the system.
2. Select System.
3. Select the System Events tab and then the Configuration sub-tab.
4. The QoS Parameters are used by the system to trigger alarms The default settings match the limits usually
acceptable for good call quality,
5. If the settings are adjusted, save the configuration back to the IP Office system.

Table of Contents