Procedure
1. On the Main Menu of Integrated RAID Controller 1: Dell <PERC H730P Mini>
Configuration Utility, click Configuration Management.
2. Click Create Virtual Disk.
If there is no option to create a virtual disk, then all disks in the system must already be
assigned to an array. You must delete all the existing configuration before creation of a
new virtual disk.
3. Configure the virtual disk parameters as follows:
a. In Select RAID Level, select the RAID level specified by the appropriate Avaya
Converged Platform configuration.
Following are the RAID configurations for Avaya Converged Platform.
Avaya Converged Platform 1XX Profile 2 = 3x600 GB > RAID5
Avaya Converged Platform Profiles 3&4 = 4x600 GB > RAID6
Avaya Converged Platform Profile 5 = 6x600 GB > RAID6
Avaya Converged Platform Profile 51 = 8x600GB > RAID6
b. In Virtual Disk Name, do not change the default value, that is, VD0, unless you are
specified another Virtual Disk Name.
c. Under Configure Virtual Disk Parameters, set the Strip Element Size value to 256
KB.
Configuration