Table 10-107. TEST #595 LANBIC Receive Parity Error Counter Test
Error
Code
Te s t
Result Description/Recommendation
2000 ABORT Response to the test was not received from the circuit pack
within the allowable time period.
1. If the test aborts repeatedly a maximum of five times,
reset the circuit pack via the busyout board PCSS and
reset board PCSS commands.
2. If the test aborts again, replace the circuit pack.
2100 ABORT Could not allocate the necessary system resources to run this
test.
2012 ABORT Internal System Error
1. Retry the command at 1-minute intervals a maximum of 5
times.
1-10 FAIL The circuit pack is still detecting errors of this type. The error
code indicates the value of the on-board error counter.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to fail, verify the validity of the Packet
Bus. Run the Packet Bus maintenance test with the test
pkt P long command. If any Packet Bus tests fail, refer to
the PKT-BUS (Packet Bus) Maintenance documentation
for recommended repair procedures.
3. If the Packet Bus test passes, check the validity of the
circuit pack. Execute a test that involves data
transmission onto the Packet Bus. For example, the BRI
may use the connectivity tests of the port-level
maintenance object (BRI-PORT) by executing the test
port PCSSpp command. Refer to the repair procedures
for the executed test if it fails. Otherwise, proceed to the
next step.
4. Other circuit packs on the Packet Bus may be the cause
of the parity error. Use the display errors command to
check the Error Log for other circuit packs that are
alarmed. If any alarms are present for the other circuit
packs, retire those alarms also. Then, rerun the LANBIC
Receive Parity Error Counter Test (#595) on this circuit
pack.
PASS No errors detected by circuit pack.