Maintenance Object Repair Procedures
555-233-123
10-398 Issue 4 May 2002
o. Error Type 3073: Remote Socket Control Link (RSCL) or Link Status Test
(#601) failed. This failure may be due to:
■ This circuit pack
■ The packet bus
■ The packet interface circuit pack.
p. Error Type 3330: Critical failure in Packet Bus interface.
Below, Error Types correspond to descriptions.
1. Attempt to clear the alarm (reset board UUCSS).
2. If alarm persists, replace circuit pack.
q. Error Type 3586 and 3999: Switch removed hyperactive circuit pack that
reported threshold number of errors. One or more of the following
symptoms may be present:
■ Circuit pack port tests return NO BOARD.
■ List configuration command shows circuit pack and ports are
installed properly
If: Then:
RSCL disconnects at link level Link fails
Link cannot be reconnected quickly Switch raises MINOR alarm
If the switch detects: Then it:
1 error, Resets circuit pack.
2 errors in 15 minutes, Raises MINOR alarm.
If Error Type 3999:
And traffic
volume is: Then:
Does not accompany
Error Type 3586,
Heavy Circuit pack is in service, but sent
at least half hyperactive
threshold. With heavy traffic, this
is normal.
Does not accompany
Error Type 3586,
Light Circuit pack is in service, but sent
at least half hyperactive
threshold. With light traffic, this
error indicates a problem with the
circuit pack, its links, or the
equipment attached to the links.
Accompanies Error
Type 3586,
Either Light or
Heavy
Switch removed hyperactive
circuit pack.