FL-DATA (Flash Data Consistency)
Issue 4 May 2002
10-835555-233-123
44 FAIL The update files, load vintages, and announcements are
different in both SPEs. The Active SPE has the most
current update file and announcements.
45 FAIL The update files, load vintages, translations, and
announcements are different in both SPEs. The Active
SPE has the most current update file, translations, and
announcements.
46 FAIL The update files, load vintages, translations, and
announcements are different in both SPEs. The Active
SPE has the most current update file and announcements,
and the Standby SPE has the most current translations.
1. Follow the procedures for Error Code 4 to get the
correct load vintage. Be sure to save the
announcements. After running test card-mem long,
check for Error Codes 32 or 64. Follow the recovery
procedure under the applicable error code.
48 FAIL The update files and announcements are different in both
SPEs. The Active SPE has the most current update file,
and the Standby SPE has the most current
announcements.
1. Follow the procedures for Error Code 40.
49 FAIL The update files, translations, and announcements are
different in both SPEs. The Active SPE has the most
current update file and translations, and the Standby SPE
has the most current announcements.
50 FAIL The update files, translations, and announcements are
different in both SPEs. The Active SPE has the most
current update file, and the Standby SPE has the most
current translations and announcements.
1. Follow the procedures for Error Code 41.
Table 10-303. TEST #421 Flash Data Consistency Check Test — Continued
Error Code
Te s t
Result Description/Recommendation
Continued on next page