Port Status Query Test (#1407)
This test is non-destructive
This test queries the Port status.
Table 10-409. port Status Query Test (#1407)
Error
Code
Test
Result Description/Recommendation
1 ABORT This port is Out of service (OOS) due to:
■ A board level problem, for example no IP address has
been translated for this location.
■ A DSP hardware problem (See Test (#1380) and Test
(#1382).
2 ABORT This port has been made maintenance busy
1002 ABORT The system could not allocate timeslots for the test. The system
may be under heavy traffic conditions or it may have timeslots out
of service due to TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling
heavy traffic, retry the command at 1-minute intervals a
maximum of 3 times.
2. If system has TDM-BUS errors, clear any errors, and
retry the command at 1-minute intervals a maximum of
3 times.
3. If the command continues to abort, escalate the
problem.
2000 ABORT Response to the test was not received in the allowable time
period.
1. Retry the command at 1-minute intervals a maximum
of 3 times.
2100 ABORT Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum
of 3 times.
2500 ABORT Internal system error.
1. Retry the command at 1-minute intervals a maximum
of 3 times.
Continued on next page