PMS-LINK (Property Management System Link)
Issue 4 May 2002
10-1325555-233-123
Hardware Error Log Entries and Test to Clear
Val ues
Notes:
a. The PMS Link has been busied out for system technician-demanded
maintenance via the busyout pms-link command. The link is torn down.
Enter the release pms-link command to restore the link.
PMS Link Maintenance Error Log Entries
Error Type Aux Data Associated Test
Alarm
Level
On/
Off
Board Test to Clear Value
0
1
1 Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test pms sh r 1
18 (a) 0 busyout pms-link WARNING OFF release pms-link
257 (b) 0-6,
99,
255
Link Retry Test
(#215)
MINOR/
WARNING
2
2 Minor alarms on this MO may be downgraded to Warning alarms based on the value used in the
set options command.
OFF test pms-link l
513 (c) 0-6,255 None test pms-link
769 (d) 0-6,255 None
1025 (e) 4x
3
3 Is any integer.
None
1281 (f) 1x
3
None
1537 (g) Nx
3
None
1793 (h) 0-6,255 None test pms-link
2049 (i) 0-6,255 None
2305 (j) 5x
3
None release pms-link or test
pms-link
2561 (k) 0-6,255 None test pms-link
2817 (l) 10x
3
20x
3
30x
3
None
3073 (m) 7x
3
None
3841 (n) 2x
3
None