test analog-testcall
Issue 4 May 2002
8-419555-233-123
Feature Interactions
■ Additional data is available after running a test. See the ‘‘list measurements
ds-1’’ command with the test-call option for details on how to access the
additional data.
■ If the trunk is in use by call processing, the test aborts.
■ If the trunk is in use by maintenance, the test queues and runs when the
current maintenance activity finishes.
Output
The following example shows the output for test analog-testcall trunk 78. The
responses display on a test-by-test basis with one line of data for each test result.
Field descriptions
Port
The port address (cabinet-carrier-slot-circuit) of the maintenance
object that is being tested.
Maintenance
Name
The type of maintenance object that is being tested.
Alt. Name
Alternate way to identify maintenance objects.
xxx/yyy (where xxx = trunk group, yyy = member)
Test No.
The test being executed
Result
Test result: Pass, Fail, Abort, Disabled, No Board, or Extra Board.
Error Code
Numeric code explaining why the release failed or aborted. Refer
to the detailed list of the codes by test number for each MO.
test analog-testcall trunk 78
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01C1505 CO-TRK 78/1 845 PASS
01C1507 CO-TRK 78/2 845 PASS
Command Successfully Completed