test analog-testcall
Issue 4 May 2002
8-419555-233-123
Feature Interactions
Additional data is available after running a test. See the ‘‘list measurements
ds-1’’ command with the test-call option for details on how to access the
additional data.
If the trunk is in use by call processing, the test aborts.
If the trunk is in use by maintenance, the test queues and runs when the
current maintenance activity finishes.
Output
The following example shows the output for test analog-testcall trunk 78. The
responses display on a test-by-test basis with one line of data for each test result.
Field descriptions
Port
The port address (cabinet-carrier-slot-circuit) of the maintenance
object that is being tested.
Maintenance
Name
The type of maintenance object that is being tested.
Alt. Name
Alternate way to identify maintenance objects.
xxx/yyy (where xxx = trunk group, yyy = member)
Test No.
The test being executed
Result
Test result: Pass, Fail, Abort, Disabled, No Board, or Extra Board.
Error Code
Numeric code explaining why the release failed or aborted. Refer
to the detailed list of the codes by test number for each MO.
test analog-testcall trunk 78
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01C1505 CO-TRK 78/1 845 PASS
01C1507 CO-TRK 78/2 845 PASS
Command Successfully Completed