PARTNER
®
Advanced Communications System Installation, Programming, and Use
B. System Specifications
15
Table 3. Other Specifications
Specification Value
Switch Fabric ■ Full digital, nonblocking
Electrical
Specifications
■ 35 Watts (120 BTUs/hr.) per ACS processor module during normal power
consumption
■ 45 Watts (154 BTUs/hr.) per ACS processor module during maximum
power consumption
■ 10 Watts (35 BTUs/hr.) per 400 module, normal and maximum power
consumption
■ 25 Watts (90 BTUs/hr.) per 206 module during normal power
consumption
■ 35 Watts (120 BTUs/hr.) per 206 module during maximum power
consumption
■ 30 Watts (105 BTUs/hr.) per 308EC module during normal power
consumption
■ 40 Watts (140 BTUs/hr.) per 308EC module during maximum power
consumption
■ 10 Watts (35 BTUs/hr.) per 1600 DSL module during normal and
maximum power consumption
■ 10 Watts (35 BTUs/hr.) per T1 module during normal and maximum
power consumption
■ U.S., Canada, and other 110V countries:
— ACS processor module and one 206 module (2-Slot carrier) = 2.3
Amps max. current, full system capacity
— ACS processor module and four 206 modules (5-Slot carrier) = 4
Amps max. current, full system capacity
■ Countries using 220V:
— ACS processor module and one 206 module (2-Slot carrier) = 1.2
Amps max. current, full system capacity
— ACS processor module and four 206 modules (5-Slot carrier) = 2
Amps max. current, full system capacity
■ 45 days to 6 months memory backup with 2 AAA-size standard alkaline
batteries (IEC LR03)
Processor Module
Specifications
■ 68306 16 Mhz processor
■ 256 Kbyte RAM
■ 512 Kbyte FLASH ROM
■ Custom VLSI DSP ASIC—16 bit, 52 Mhz
— VLSI = Very Large Scale Integration
— DSP = Digital Signal Processor
— ASIC = Application Specific Integrated Circuit