PARTNER
®
Advanced Communications System Installation, Programming, and Use
B. System Specifications
16
Extension Jack
Specifications
(206 module)
■ Ringing voltage: +5 VDC, -140 VDC peak to peak; trapezoidal wave
shaping
■ 35- to 38-Volt talk battery
■ Ringing frequency: 20 Hz
Extension Jack
Specifications
(ACS Processor
and 308EC
module)
■ Ringing voltage: +55 VRMS Balanced ringing within a trapezoidal wave
shaping
■ 38- to 42-Volt talk battery
■ Ringing frequency: 20 HZ
Extension Jack
Specifications
(012E module)
■ Ringing voltage: +55 VRMS Balanced ringing within a trapezoidal wave
shaping
■ 38- to 42-Volt talk battery
■ Ringing frequency: 20 HZ
PAGE Jack
Specifications
■ Draws current on inner wire pair
■ Provides paging contact closure on outer wire pair
■ 600 Ohm impedance
Music-on-Hold
Jack
Specifications
■ Accepts 2 Volts at 50 Kohms maximum input
■ 0 - 18 dB attenuation
CONTACT
CLOSURE
Adjunct Jack
Specifications
■ Operates up to 150 feet (45.72 meters) from control unit using 24 gauge
solid conductor wire if 2 Contact Closures used; up to 800 feet (243.84
meters) from control unit using 24 gauge solid conductor wire if only 1
Contact Closure used
■ Install the Contact Closure Adjunct in the same building as the control
unit; cannot be installed out-of-doors
■ Has three terminals per Contact Closure, providing a normally open and
normally closed function for each Contact Closure
■ Maximum contact voltages and current:
— 30 VAC, 1 Amp
— 50 VDC, 1 Amp
SMDR Output
Format
■ 1200 baud
■ 8 data bits
■ XON/XOFF protocol
■ Line feeds
■ No parity
■ 2 stop bits
■ Carriage return
Table 3. Other Specifications—Continued
Specification Value