EasyManua.ls Logo

Avaya PARTNER Advanced Communications System - Page 16

Avaya PARTNER Advanced Communications System
18 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PARTNER
®
Advanced Communications System Installation, Programming, and Use
B. System Specifications
16
Extension Jack
Specifications
(206 module)
Ringing voltage: +5 VDC, -140 VDC peak to peak; trapezoidal wave
shaping
35- to 38-Volt talk battery
Ringing frequency: 20 Hz
Extension Jack
Specifications
(ACS Processor
and 308EC
module)
Ringing voltage: +55 VRMS Balanced ringing within a trapezoidal wave
shaping
38- to 42-Volt talk battery
Ringing frequency: 20 HZ
Extension Jack
Specifications
(012E module)
Ringing voltage: +55 VRMS Balanced ringing within a trapezoidal wave
shaping
38- to 42-Volt talk battery
Ringing frequency: 20 HZ
PAGE Jack
Specifications
Draws current on inner wire pair
Provides paging contact closure on outer wire pair
600 Ohm impedance
Music-on-Hold
Jack
Specifications
Accepts 2 Volts at 50 Kohms maximum input
0 - 18 dB attenuation
CONTACT
CLOSURE
Adjunct Jack
Specifications
Operates up to 150 feet (45.72 meters) from control unit using 24 gauge
solid conductor wire if 2 Contact Closures used; up to 800 feet (243.84
meters) from control unit using 24 gauge solid conductor wire if only 1
Contact Closure used
Install the Contact Closure Adjunct in the same building as the control
unit; cannot be installed out-of-doors
Has three terminals per Contact Closure, providing a normally open and
normally closed function for each Contact Closure
Maximum contact voltages and current:
30 VAC, 1 Amp
50 VDC, 1 Amp
SMDR Output
Format
1200 baud
8 data bits
XON/XOFF protocol
Line feeds
No parity
2 stop bits
Carriage return
Table 3. Other Specifications—Continued
Specification Value

Other manuals for Avaya PARTNER Advanced Communications System