PARTNER
®
Advanced Communications System Installation, Programming, and Use
System Reset—Programming Saved (#728)
4-62
Programming 4
To program a System Password:
1. Press
f00ss#403 at extension 10 or 11. A display
similar to the following appears:
Set System Password
Data - - - - - - - - - - - -
2. Enter a four-digit password, or press
r to delete the existing password.
3. Select another procedure, or exit programming mode.
System Reset—Programming Saved (#728) 4
Use this feature to reset the system while retaining the currently programmed settings. Reset the
system only when advised to do so by technical support personnel.
Considerations 4
■ Resetting the system disconnects all active calls.
■ This procedure is skipped in the sequence of programming procedures when cycling. To use
this procedure, enter the code directly.
■ The system reset begins immediately and takes only a few seconds.
■ You cannot interrupt the reset process or use any telephones in the system during the reset
process.
■ Most of the system and telephone programming settings that were in effect before the power
failure or down period are retained; they do not revert to the default settings.
■ Automatic System Answer Button (#111), Direct Extension Dial Button (#113), Night
Service Button (#503), and Station Lock return to the status (on or off) that they were in
immediately prior to the system reset.
■ The VMS Cover button and Privacy button return to the status (on or off) determined by the
programmed setting of Automatic VMS Cover (#310) and Automatic Extension Privacy
(#304), respectively. For example, if Automatic Extension Privacy is Assigned and the
Privacy button is on when a system reset occurs, the Privacy button will be on again after the
system reset. However, if Automatic Extension Privacy is Not Assigned and the Privacy
button is on when a system reset occurs, the Privacy button will be off after the system reset.
■ A successful use of Restore Programming (#125) causes a System Reset—Programming
Saved to occur.
■ The information stored in the Save Number Redial (F04) and the Last Number Redial (F05)
buffers is lost when a System Reset—Programming Saved occurs.
■ You can use System Reset—Programming Saved to restore the configuration in the 1600
DSL module.