System Capacity
1-10
■ PARTNER ACS Release 6.0 or later systems allow up to 31 lines and up to 48 extensions;
however, these maximums cannot be achieved simultaneously.
Table 1-5. Release 6.0 or Later Capacities
Configuration Maximum Lines Maximum Extensions
Stand-alone 3 lines, 8 extensions
PARTNER ACS processor module
8 extensions, 3 lines
PARTNER ACS processor module
2-slot carrier 19 lines, 8 extensions
Processor module and T1 module
20 extensions, 3 lines
Processor module and 012E module
5-slot carrier 31 lines, 8 extensions
Processor module, T1 module or
1600 DSL module, and three 400
modules
44 extensions, 19 lines
Processor module, T1 module or
1600 DSL module, and three 012E
modules
OR
48 extensions, 9 lines
Processor module, two 308EC
modules, and two 012E modules
■ In Release 6.0, the system extension maximum is 48. However, in some
configurations, the 012E module and/or the PARTNER Messaging module will
physically permit more than 48 stations to be installed in the 5-slot carrier. In these
configurations, only station ports and voice messaging ports up to 48 will function.
Station ports and voice messaging ports above 48 will not function with ETR or T/R
telephones because they are outside the PARTNER ACS dial plan.
■ You can have only one T1 module in a system.