Converting some or all direct-connect port networks to IP-connect
1068 Upgrading, Migrating, and Converting Media Servers and Gateways
Tip:
Tip: Enter list cabinet to see a list of all the cabinets and the PNs that the
cabinets contain.
3. In the Primary field, enter a synchronization-source circuit pack location. Obtain this
location from the “Circuit Packs Available for Synchronization” list. Ensure that you choose
a working synchronization source.
In the example, location 03B03 is the primary synchronization source for PN 3.
4. Optionally, add another synchronization-source circuit pack location in the Secondary field.
Obtain the location from the “Circuit Packs Available for Synchronization” list.
5. Press Submit.
6. Wait about 5 minutes for Communications Manager to update the synchronization plan.
Then to check the changes, enter list synchronization and the status
synchronization commands.
7. If the Switching Capability field for this PN is disabled on the Synchronization Status
screen, enter enable synchronization-switch all.
8. To check for errors, enter test synchronization port-network n long. All listed
ports must show PASS in the Results field. If the Results field does not show PASS, you
must troubleshoot the synchronization error.