Maintenance-Object Repair Procedures
555-233-143
8-380 Issue 1 May 2002
1187 ABORT The circuit pack, port or station may have been busied out by a technician.
1. Look in the Error Log for Error Type 18 (busied out) for BRI-BD, BRI-PORT,
or BRI-SET.
a. If this error type is present for BRI-SET only, then release the station via
the release station
b. If this error type is present for BRI-PORT and BRI-SET, then release
the port via the release port PCSSpp command and run the test again.
c. If the error is present for BRI-BD, BRI-PORT, and BRI-SET, then
release the circuit pack via the release port PCSSpp command and
run the test again. If the error is present for both BRI-BD and
BRI-PORT, then release the circuit pack via the release board PPCSS
command and run the test again.
NOTE:
When you release the circuit pack, you release every port associated
with it. If certain ports still need to be busied out, use the busyout port
PCSSpp command to busy them out.
2. Make sure the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
4. If the test continues to abort, escalate the problem.
2012 ABORT Internal system error.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
PASS The switch has successfully executed the BRI station audits.
Table 8-159. Test #630 BRI Set Audits — Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page