FIBER-LK (Fiber Link)
Issue 1 May 2002
8-863555-233-143
Table 8-331. Test #989 SNI Fiber Out of Frame Query
Error
Code
Tes t
Result Description / Recommendation
1415 ABORT The lightwave transceiver is absent from Endpoint 1 of the fiber link (list
fiber-link can be used to display fiber link endpoints).
1. If a lightwave transceiver should not be present (for example, an SNI
connected to a DS1 CONV circuit pack), do nothing.
2. Otherwise, continue with the following steps.
3. Check the lightwave transceiver connections.
4. Replace the lightwave transceiver.
5. Replace the SNI circuit pack.
1416 ABORT The lightwave transceiver is absent from Endpoint 2 of the fiber link (list
fiber-link can be used to display fiber link endpoints).
1. If a lightwave transceiver should not be present (for example, an SNI
connected to a DS1 CONV circuit pack), do nothing.
2. Otherwise, continue with the following steps.
3. Check the lightwave transceiver connections.
4. Replace the lightwave transceiver.
5. Replace the SNI circuit pack.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2300 ABORT The downlink message necessary to run this test could not be sent.
1. Retry the command at 1-minute intervals up to 3 times.
2301 ABORT The software timer could not be set before sending the downlink message
necessary to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2304 ABORT The SNI circuit pack responded that it is not able to run the test requested by
software.
1. Retry the command at 1-minute intervals up to 3 times.