M/T-DIG (Maintenance/Test Digital Port)
Issue 1 May 2002
8-1165555-233-143
Table 8-477. Test #9 NPE Cross Talk Test
Error
Code
Tes t
Result Description / Recommendation
1000 ABORT System resources required to run this test are not available. The port may be
in use on a valid ISDN-PRI test call. Use the list isdn-testcall command to
determine whether the port is in use (listed in the M/T Port column). If so,
either wait for the test call to finish (as indicated in the
Start Time and
Duration fields in the above display), or abort the test call with the clear
isdn-testcall grp/mem command, where grp/mem is determined from the
B-channel field of the above display.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort and the port is idle, escalate the problem.
1001 ABORT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
1002 ABORT The system could not allocate time slots for the test. The system may be under
heavy traffic conditions or it may have time slots out of service due to
TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat test at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
1003 ABORT The system could not allocate a tone receiver for the test. The system may be
oversized for the number of tone detectors present or some tone detectors may
be out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the test at 1-minute intervals up to 5 times.
4. If the test continues to abort, escalate the problem.
1004 ABORT The port has been seized by a valid ISDN-PRI test call. Use the list
isdn-testcall command to determine which call is using the port (from the
M/T Port column). Either wait for the test call to complete (as indicated in the
Start Time and Duration fields of the above display), or abort the test
call with the clear isdn-testcall grp/mem command, where grp/mem is
determined form the
B-channel field of the above display.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort and the port is idle, escalate the problem.
Continued on next page