Maintenance-Object Repair Procedures
555-233-143
8-1346 Issue 1 May 2002
Table 8-545. Digital Line Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
tests description, and follow its recommended procedures.
0Any Any Anytest port UUCSSpp sh r 1
1 (a) 1 20,
40987
None WARNING OFF
18 (b) 0 busyout port UUCSSpp WARNING OFF re port UUCSSpp
257 (c) 40971 None
513 (d) 0 Station (Digital) Audits test
(#17)
WARNING OFF test port UUCSSpp sh r 6
767 (e) 40964 None WARNING OFF
769 (f) 40963,
40988
None WARNING OFF
1025 (g) None WARNING OFF
1281 Any Station (Digital) Audits test
(#17)
WARNING OFF test port UUCSSpp sh r 4
1537 (h) 40968 None WARNING OFF
2304 (i) None
2305 (j) 32770,
40967
None
2817 (k) Hyperactive MINOR OFF
3840 (l) 40965,
40989
None
3841 (m) 41029 None
Continued on next page