Maintenance Commands
555-233-143
7-280 Issue 1 May 2002
Associated Link MOs affected
by this Command
NOTE:
Although alarms on these MOs may appear as warnings, the alarms should
be investigated with user-related problems.
■ PN’s Maintenance circuit pack (MAINT)
■ Expansion Interface (EXP-INTF)
■ ISDN-PRI signaling group (ISDN-SGR)
■ Journal printer (JNL-PRNT)
■ PMS link (PMS-LINK)
■ Primary CDR link (PRI-CDR)
■ Synchronization (SYNC)
■ System printer (SYS-PRNT)
■ TDM clock (TDM-CLK)
■ Tone Generator circuit or circuit pack (TONE-BD)
Field Help
Since every field on the first page may have the same values, pressing HELP in
any field of this page presents the following help message:
m(inor) n(o) r(eport) w(arning) y(es)
The following is a description of the values:
Every field on page 2 may have the same values. Pressing HELP in any field of
page 2 gives the following field help message:
Enter alarm group number: 1 to 4
The alarm group number is a way of distinguishing four different groups of alarms.
These alarm groups allow the user to specify that alarms in different groups are
handled differently from those in other groups.
m(inor)
Downgrade the major alarm to a minor alarm and report the alarm to INADS.
n(o)
Do not log the alarm or report it to INADS.
r(eport)
Downgrade the alarm to a warning and report the warning to INADS.
w(arning)
Downgrade the alarm to a warning, log it but do not report the alarm to INADS.
y(es)